Electric Insulation Fiberglass Insulating Banding Tape

Application: Electrical Winding Insulation, Winding Wire Coating Insulation, Motor
Color: White
Material: Glass Fiber
Maximum Voltage: 20KV~100KV
Thermal Rating: H 180
Width: 10mm, 15mm, 20mm, 25mm, 30mm, 32mm, 35mm, 40mm

Products Details

Basic Info.

Model NO.
LT-PGW
Thickness
0.17mm, 0.2mm, 0.25mm, 0.3mm, 0.32mm
Raw Material
Fiber Glass Yarn + Unsaturated Polyester Rein
Package
50~200 Meters Per Roll
Thermal Grade
F, H Grade
Type
Solid
Chemistry
Inorganic Insulation
Classification
Inorganic Insulation Material
Certification
ISO9001
Brand
Lontom
Transport Package
Spool
Specification
RoHS
Trademark
LONTOM
Origin
Shanghai, China
HS Code
70199000
Production Capacity
1000000 Rolls Per Month

Product Description

Electric Insulating Edge Banding Tape
1.Thickness:0.2~0.5mm
2.Fiberglass banding tape
3.Self-adhesive insulation tape
4.SGS,RoHS


The banding tapes are of high quality, which consist of parallel twisted E-glass yarns preimpregnated with a special thermosetting polyester resin and manufactured with the proprietory technology and advanced equipments.

It's widely used in AC. DC motors, generators and transformers especially in traction motors.


 Main Properties:

1.Thickness: 0.20mm±10%,0.30mm±10%
 
2.Width: 10mm~50mm±10%
 
3.Length/Spool: 50~200 meters
 
4.Standard color: White

5.Thermal Grade: F grade(155ºC)
                 H grade(180ºC)


6.Curing condition (Time to bring the piece to the temperature is not considered)
Temperature ºC 160 150 135 120 115
Time hour 2.5 3 5 14 20
 
7.Storage Stability:
Storage temperature ºC 10 15 20 30
Time Month 20 15 10 6


Electric Insulation Fiberglass Insulating Banding Tape
Technical Data:

Test content Unit Standard Value  
Thermal class   H F  
Volatile content % 2  
Loss of weight at calcination % 26±2  
Soluble resin content % 90  
Tensile strength before curing N/cm 1500 1000  
Maximum pull while banding N/cm 800 800  
Tensile strength of ringlike sample at room temperature after curing Mpa 20ºC  
above :900 above :900  
Tensile strength of ringlike sample at working temperature after curing Mpa 180ºC 150ºC  
600 560  
Proof tracking index   500V  
Arc resistance S 160  
Breakdown voltage parallel to layers KV normal condition:25
after soaked in water for 24 hours:10
 
Thermosetting OK  
Loss of tensile strength after soaked in oil 10%  
 

Package:
Electric Insulation Fiberglass Insulating Banding Tape

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours